Position : Home > Product > YOKOGAWA > Pressure Transmitters

EJX910A Multivariable Transmitter
  • EJX910A Multivariable Transmitter

EJX910A Multivariable Transmitter

Details

Yokogawa EJX910A Multivariable Transmitter

 

Introducing the Yokogawa EJX910A multivariable transmitter, a remarkable innovation in multi-sensing technology that makes optimal use of the powerful characteristics of the single-crystal silicon resonant sensor. Experience EJXMVTool™(FSA120), PC-based software that is exclusively designed for use with the EJX910A. EJXMVTool™ enables users to configure mass flow and achieve accurate measurements with real-time full density compensation. Key features include:
1.0% mass flow rate accuracy
Fully compensated mass flow: all flow factors can be automatically and dynamically calculated to an optimal value
Fully compensated mass flow: all flow factors can be automatically and dynamically calculated to an optimal value
Simultaneous dual output of 4 to 20 mA and pulse signals for total flow, flow rate, or alarm status
Various function blocks available;
5 Als, AR, IT, SC, and IS as standard 
PID as an optional feature
Cyclically displays up to 10 variables
Software download function(option)
Advanced diagnostic function (option)
 

Downloads for EJX910A

General Specifications

 

Specifications

 

 

EJX910A Multivariable Transmitter

L Capsule

M Capsule

H Capsule

Range

Differential pressure

-10 to 10

-100 to 100

-500 to 500

kPa

kPa

kPa

(-40 to 40

(-400 to 400

(-2000 to 2000

inH2O)

inH2O)

inH2O)

Static

Absolute

0 to 16 MPa abs

0 to 25 MPa abs

pressure

(0 to 2300 psia)

(0 to 3600 psia)

 

Gauge

-0.1 to 16 MPa

-0.1 to 25 MPa

 

(-14.5 to 2300 psig)

(-14.5 to 3600 psig)

External temperature

-200 to 800 deg C (-328 to 1472 deg F)

Span

Differential pressure

0.1 to 10 kPa

0.5 to 100 kPa

2.5 to 500 kPa

(0.4 to 40 inH2O)

(2 to 400 inH2O)

(10 to 2000 inH2O)

Static

Absolute

1 to 16 MPa

1 to 25 MPa

pressure

Gauge

(145 to 2300 psi)

(145 to 3600 psi)

External temperature

10 to 1050 deg C (18 to 1890 deg F)

Accuracy

Mass flow

±1.0%

Differential pressure

±0.04%

Static pressure

±0.1%

External temperature

±0.5 deg C (±0.9 deg F)

Flow

Primary

Orifice

ISO 5167-1:1991, ISO 5167-2:2003,

calculation

device

ASME MFC-3M-1989

reference

 

Nozzle

ISO 5167-1:1991, ISO 5167-3:2003,

 

 

ASME MFC-3M-1989

 

 

Venturi

ISO 5167-1:1991, ISO 5167-4:2003,

 

 

ASME MFC-3M-1989

 

Density

General fluid

DIPPR (Physical property database)

 

compensation

Natural gas

AGA No. 8, ISO 12213

 

of fluid

Steam

IAPWS-IF97 Water and Steam, 1997

 

 

Manual mode

Flow factors being input manually

Degrees of protection

IP67, NEMA 4X, and JIS C0920 immersion proof

Certificates

FM, CENELEC ATEX, CSA, IECEx

Output

[HART protocol type]

Dual output of 4 to 20 mA with pulse signals

[FOUNDATION™ fieldbus type]

FOUNDATION™ fieldbus,2-wire system with

digital communication

Supply voltage

HART:10.5 to 42 V DC

(10.5 to 30 V DC for Intrinsically safe type)

Fieldbus:9 to 32 V DC

Ambient temperature

-40 to 85 deg C (-40 to 185 deg F)

(general use type)

-30 to 80 deg C (-22 to 176 deg F)

(with integral indicator)

Process temperature

-40 to 120 deg C (-40 to 248 deg F)

(general use type)

Maximum working pressure

16 MPa

25 MPa

(2300 psi)

(3600 psi)

Mounting

2-inch pipe mounting

Wetted parts

Capsule

316L SST (Diaphragm material is Hastelloy C-276)

material

Cover flange

ASTM CF-8M

Housing

Cast aluminum alloy

Flow configuration tool

EJXMVTool™

EJX-MV

 

 

 

分享到:
Hits:  UpdateTime:1022  【Printing】  【Close